<?xml version="1.0"?>
<Articles JournalTitle="Frontiers in Biomedical Technologies">
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Biomedical Technologies</JournalTitle>
      <Issn>2345-5837</Issn>
      <Volume>4</Volume>
      <Issue>1-2</Issue>
      <PubDate PubStatus="epublish">
        <Year>2017</Year>
        <Month>06</Month>
        <Day>30</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Assessment of a Linear Phased Array Transducer Parameters for Brain Stimulation</title>
    <FirstPage>1</FirstPage>
    <LastPage>17</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName>Maryam</FirstName>
        <LastName>Salehnia</LastName>
        <affiliation locale="en_US">Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran. AND Research Center for Molecular and Cellular Imaging (RCMCI), Tehran University of Medical Sciences, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Hossein</FirstName>
        <LastName>Ghadiri</LastName>
        <affiliation locale="en_US">Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran. AND Research Center for Molecular and Cellular Imaging (RCMCI), Tehran University of Medical Sciences, Tehran, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2017</Year>
        <Month>12</Month>
        <Day>04</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2017</Year>
        <Month>12</Month>
        <Day>05</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Purpose: Transcranial focused ultrasound (tFUS) is a safe method with high resolution to stimulate the brain tissue. By appropriate beam-forming, using a phased array transducer enables us to focus on the desired position with high resolution without moving the transducer.
Methods: In this paper, the physics of tFUS propagated from a linear phased array transducer, in a 2-dimensional environment, is simulated using the k-space pseudospectral method. Furthermore, we study some factors affecting the spatial accuracy of focus point including the length of the transducer and its elements, the beam-forming and the amplitude of input pressure signal. Also, the thickness of the bone layer and the depth of focus as environmental features are considered subsequently. 
Results: We investigate these parameters to propose optimum conditions in the transcranial focusing. The main contribution of this research includes: 1. computing tissue-sensitive time delays of transducer elements, 2. providing a minimum possible length of the transducer and 3. Using a neural network to determine the best possible value of the amplitude of the input pressure to get desired focus pressure that was not possible before. 
Conclusion: Based on our experiments, we obtain a significant decrease of about 32 units in the maximum error and fit a function to estimate the pressure with a correlation coefficient of approximately 0.9997.</abstract>
    <web_url>https://fbt.tums.ac.ir/index.php/fbt/article/view/155</web_url>
    <pdf_url>https://fbt.tums.ac.ir/index.php/fbt/article/download/155/96</pdf_url>
  </Article>
</Articles>