<?xml version="1.0"?>
<Articles JournalTitle="Frontiers in Biomedical Technologies">
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Biomedical Technologies</JournalTitle>
      <Issn>2345-5837</Issn>
      <Volume>9</Volume>
      <Issue>4</Issue>
      <PubDate PubStatus="epublish">
        <Year>2022</Year>
        <Month>07</Month>
        <Day>31</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Is the Electronic Exchange of Patient Information among Iranian Healthcare Organizations a Distant Dream?</title>
    <FirstPage>246</FirstPage>
    <LastPage>247</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Negisa</FirstName>
        <LastName>Seyyedi</LastName>
        <affiliation locale="en_US">Nursing Care Research Center, Iran University of Medical Sciences, Tehran, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2022</Year>
        <Month>05</Month>
        <Day>26</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2022</Year>
        <Month>06</Month>
        <Day>21</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">No Abstract. No Abstract. No Abstract.</abstract>
    <web_url>https://fbt.tums.ac.ir/index.php/fbt/article/view/499</web_url>
    <pdf_url>https://fbt.tums.ac.ir/index.php/fbt/article/download/499/265</pdf_url>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Biomedical Technologies</JournalTitle>
      <Issn>2345-5837</Issn>
      <Volume>9</Volume>
      <Issue>4</Issue>
      <PubDate PubStatus="epublish">
        <Year>2022</Year>
        <Month>06</Month>
        <Day>20</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Improving the Classification of Real-World SSVEP Data in Brain-Computer Interface Speller Systems Using Deep Convolutional Neural Networks</title>
    <FirstPage>248</FirstPage>
    <LastPage>254</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Elham</FirstName>
        <LastName>Rostami</LastName>
        <affiliation locale="en_US">Department of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Farnaz</FirstName>
        <LastName>Ghassemi</LastName>
        <affiliation locale="en_US">Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic)</affiliation>
      </Author>
      <Author>
        <FirstName>Zahra</FirstName>
        <LastName>Tabanfar</LastName>
        <affiliation locale="en_US">Department of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2021</Year>
        <Month>08</Month>
        <Day>30</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2021</Year>
        <Month>11</Month>
        <Day>03</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Purpose: Brain-Computer Interface (BCI) Speller systems help people with mobility impairments improve their cognitive and physical abilities. Steady-State Visual Evoked Potential (SSVEP) signals have been used to build high-speed BCI speller systems. SSVEP signals are a subtype of Visual Evoked Potential (VEP), a form of co-frequency, and the harmonics response elicited by a specific frequency stimulus. Noise and artifacts are critical issues for target detection in SSVEP-based BCI systems.
&#xD;

Materials and Methods: Thus, it is essential to provide target detection techniques that operate well in the presence of noises. One solution for overcoming the noise impact is to employ approaches that automatically extract the appropriate features for target detection from the training data. Deep Convolutional Neural Network (DCNN) was utilized in this study to automatically extract features from SSVEP data in noisy conditions. Moreover, the BETA database, which contains SSVEP data from 70 individuals collected outside of the electromagnetic shielding room, was used. In this regard, a suitable DCNN structure for target stimulus frequency identification was first designed. The network was pre-trained with part of the data from the BETA database. Finally, at the single-subject level, this pre-trained network was retrained and evaluated.
&#xD;

Results: The results showed that after retraining, the accuracy and Information Transfer Rate (ITR) increased (p-value &lt; 0.01) for all participants.
&#xD;

Conclusion:.The enhancement in accuracy and ITR are 25.72% and 43.10 bpm, respectively.</abstract>
    <web_url>https://fbt.tums.ac.ir/index.php/fbt/article/view/387</web_url>
    <pdf_url>https://fbt.tums.ac.ir/index.php/fbt/article/download/387/263</pdf_url>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Biomedical Technologies</JournalTitle>
      <Issn>2345-5837</Issn>
      <Volume>9</Volume>
      <Issue>4</Issue>
      <PubDate PubStatus="epublish">
        <Year>2022</Year>
        <Month>03</Month>
        <Day>04</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">A Low-Power and Wide Dynamic Range Digital Pixel Sensor for Intrinsic Optical Imaging in Image-Guided Neurosurgery and Neocortical Epilepsy</title>
    <FirstPage>255</FirstPage>
    <LastPage>264</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Yasin</FirstName>
        <LastName>Salehifar</LastName>
        <affiliation locale="en_US">School of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Ahmad</FirstName>
        <LastName>Ayatollahi</LastName>
        <affiliation locale="en_US">School of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Mohammad Azim</FirstName>
        <LastName>Karami</LastName>
        <affiliation locale="en_US">School of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Mahzad</FirstName>
        <LastName>Pirghayesh Ghurshagh</LastName>
        <affiliation locale="en_US">School of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2021</Year>
        <Month>08</Month>
        <Day>06</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2021</Year>
        <Month>11</Month>
        <Day>27</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Purpose: Determining the borders of brain tumors, seizure foci, and their elimination in patients with brain tumors is very important in preventing cancer recurrence. Multispectral Optical Intrinsic Signal Imaging (MS-OISI) image-guided neurosurgery using visible-Near-Infrared (NIR) wavelengths have shown great potential for image-guided neurosurgery. One of the main challenges is the need for low-power consumption, high-speed and above 100dB dynamic range to capture both visible and NIR photons. The overarching goal of this work is to create a Digital Pixel Sensor (DPS) as a Complementary Metal-Oxide-Semiconductor (CMOS) camera for MS-OISI of the brain in image-guided neurosurgery that has a wide dynamic range, low power consumption, and high speed.
&#xD;

Materials and Methods: The general view of neurosurgical system, DPS, and circuit operation of conventional Pulsed Frequency Modulation (PFM) DPS are given first. The proposed PFM DPS and circuit implementation are shown, as well as simulation results obtained using a circuit simulator. Finally, a comparison with other similar works is given.
&#xD;

Results: The proposed pixel simulation results show that the performance parameters such as dynamic range and power consumption has improved in comparison to similar works. However, due to its complicated circuitry, it has a low spatial resolution, which can be compensated.
&#xD;

Conclusion: The image sensor is post-layout simulated in 0.18&#x3BC;m CMOS technology with a 1.3V supply voltage, resulting in 140dB dynamic range and 7.69&#x3BC;W power dissipation with a 11% fill factor. The key novelty for the proposed PFM DPS is: in-pixel Analog-to-Digital Conversion (ADC), using a low voltage and high-speed dynamic comparator. Furthermore, this work uses a self-reset mechanism, which eliminates the need for an external pulse source, as well as variable reference voltage, which eliminates the necessity for a global constant reference voltage. All of these features demonstrate the excellent potential of the proposed pixel for MS-OISI image-guided neurosurgery.</abstract>
    <web_url>https://fbt.tums.ac.ir/index.php/fbt/article/view/375</web_url>
    <pdf_url>https://fbt.tums.ac.ir/index.php/fbt/article/download/375/251</pdf_url>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Biomedical Technologies</JournalTitle>
      <Issn>2345-5837</Issn>
      <Volume>9</Volume>
      <Issue>4</Issue>
      <PubDate PubStatus="epublish">
        <Year>2022</Year>
        <Month>07</Month>
        <Day>31</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">The Effectiveness of Repetitive Transcranial Magnetic Stimulation and Theta Burst Stimulation on Selective Attention, Working Memory and Response Time in Suicide</title>
    <FirstPage>265</FirstPage>
    <LastPage>273</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Mahjoubeh</FirstName>
        <LastName>Rahimi Doab</LastName>
        <affiliation locale="en_US">Department of Cognitive Neuroscience, Institute for Cognitive Science Studies, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Mohammad-Reza</FirstName>
        <LastName>Zarindast</LastName>
        <affiliation locale="en_US">Department of Cognitive Neuroscience, Institute for Cognitive Science Studies, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Mohammad</FirstName>
        <LastName>Nasehi</LastName>
        <affiliation locale="en_US">Department of Cognitive Neuroscience, Institute for Cognitive Science Studies, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Mehdi</FirstName>
        <LastName>Talebi</LastName>
        <affiliation locale="en_US">Department of Psychiatry, Mashhad University of Medical Sciences, Mashhad, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Peyman</FirstName>
        <LastName>Hassani Abharian</LastName>
        <affiliation locale="en_US">Department of Cognitive Neuroscience, Institute for Cognitive Science Studies, Tehran, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2021</Year>
        <Month>08</Month>
        <Day>31</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2021</Year>
        <Month>12</Month>
        <Day>01</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Purpose: Cognitive dysfunction is common in individuals with depression and these cognitive deficits may be associated with a risk of suicide. Therefore, the identification of the cognitive functions of depressed patients and the introduction of effective interventions on these factors are highly important. This study aimed to compare the effectiveness of repetitive Transcranial Magnetic Stimulation (rTMS) and Theta Burst Stimulation (TBS) to improve selective attention, working memory, and response time of depressed individuals with and without a history of suicide.
&#xD;

Materials and Methods: This applied quasi-experimental study was conducted based on a pretest-posttest design. The population included 40 depressed patients referring to the clinics of Mashhad, Iran, in 2020. The samples were divided into four groups, namely individuals with a history of suicide subjected to treatment with rTMS, without a history of suicide receiving treatment with rTMS, with a history of suicide undergoing treatment with TBS, and without a history of suicide administered with TBS (n = 10 each). The data were collected using the Stroop Color and Word Test, Corsi block test, and reaction time tests and statistically analyzed using multivariate analysis of covariance.
&#xD;

Results: The results confirmed the effectiveness of the intervention on the congruent reaction time, incongruent reaction time, working memory, simple reaction time, and selective reaction time in all four study groups (P &lt; 0.05). The results of multivariate analysis of covariance showed that the group had a significant effect on the variables of congruent reaction time, simple reaction time, and selective reaction time (P &lt; 0.05); however, it had no significant effect on the variables of incongruent reaction time and working memory (P &gt; 0.05).
&#xD;

Conclusion: Compared to the rTMS method, the TBS had a greater effect on the variables of congruent reaction time, simple reaction time, and selective reaction time.</abstract>
    <web_url>https://fbt.tums.ac.ir/index.php/fbt/article/view/396</web_url>
    <pdf_url>https://fbt.tums.ac.ir/index.php/fbt/article/download/396/266</pdf_url>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Biomedical Technologies</JournalTitle>
      <Issn>2345-5837</Issn>
      <Volume>9</Volume>
      <Issue>4</Issue>
      <PubDate PubStatus="epublish">
        <Year>2022</Year>
        <Month>07</Month>
        <Day>31</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Predicting Mini-Mental State Examination Scores Using Electroencephalography Signal Features</title>
    <FirstPage>274</FirstPage>
    <LastPage>282</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Vahid</FirstName>
        <LastName>Asayesh</LastName>
        <affiliation locale="en_US">Asab Pajouhane Farda Research Company, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Mahdi</FirstName>
        <LastName>Dehghani</LastName>
        <affiliation locale="en_US">Asayesh Rehabilitation Clinic, Tabriz, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Majid</FirstName>
        <LastName>Torabi</LastName>
        <affiliation locale="en_US">Asab Pajouhane Farda Research Company, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Sepideh</FirstName>
        <LastName>Akhtari</LastName>
        <affiliation locale="en_US">Asab Pajouhane Farda Research Company, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Shahriar</FirstName>
        <LastName>Gharibzadeh</LastName>
        <affiliation locale="en_US">Institute for Cognitive and Brain Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2021</Year>
        <Month>08</Month>
        <Day>31</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2021</Year>
        <Month>12</Month>
        <Day>05</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Purpose: The purpose of this study is to use linear and non-linear features extracted from Electroencephalography (EEG) signal to predict the Mini-Mental State Examination (MMSE) test score by machine learning algorithms.
&#xD;

Materials and Methods: First, the MMSE test was taken from 20 subjects that were referred with the initial diagnosis of dementia. Then, the brain activity of subjects was recorded via EEG signal. After preprocessing this signal, various linear and non-linear features are extracted from it that are used as input to machine learning algorithms to predict MMSE test scores in three levels.
&#xD;

Results: Based on the experiments, the best classification result is related to the Long Short-Term Memory (LSTM) network with 68% accuracy.
&#xD;

Conclusion: Findings show that by using machine learning algorithms and features extracted from EEG signal the MMSE scores are predicted in three levels. Although deep neural networks require a lot of data for training, the LSTM network has been able to achieve the best performance. By increasing the number of subjects, it is expected that the classification results will also increase.</abstract>
    <web_url>https://fbt.tums.ac.ir/index.php/fbt/article/view/395</web_url>
    <pdf_url>https://fbt.tums.ac.ir/index.php/fbt/article/download/395/267</pdf_url>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Biomedical Technologies</JournalTitle>
      <Issn>2345-5837</Issn>
      <Volume>9</Volume>
      <Issue>4</Issue>
      <PubDate PubStatus="epublish">
        <Year>2022</Year>
        <Month>07</Month>
        <Day>31</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">The Impact of VAT and SEMAC Methods on the Metal Artifact Reduction in Magnetic Resonance Imaging of the Knee Prosthesis</title>
    <FirstPage>283</FirstPage>
    <LastPage>290</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Parisa</FirstName>
        <LastName>Shahbazi</LastName>
        <affiliation locale="en_US">Department of Biomedical Engineering, Tabriz Branch, Islamic Azad University, Tabriz, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Behzad</FirstName>
        <LastName>Yasrebi</LastName>
        <affiliation locale="en_US">Department of Biomedical Engineering, Tabriz Branch, Islamic Azad University, Tabriz, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Cyrus</FirstName>
        <LastName>Afshar</LastName>
        <affiliation locale="en_US">Orthopedic Specialist, Valiasr Hospital, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Siamak</FirstName>
        <LastName>Haghipour</LastName>
        <affiliation locale="en_US">Department of Biomedical Engineering, Tabriz Branch, Islamic Azad University, Tabriz, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Razzagh</FirstName>
        <LastName>Abedi-Firouzjah</LastName>
        <affiliation locale="en_US">Department of Medical Physics Radiobiology and Radiation Protection, School of Medicine, Babol University of Medical Sciences, Babol, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2021</Year>
        <Month>08</Month>
        <Day>11</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2021</Year>
        <Month>12</Month>
        <Day>04</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Purpose: At Magnetic Resonance Imaging (MRI), artifacts arising from metal implants are an obstacle to obtaining optimal images. This study aimed to evaluate the impact of View-Angle Tilting (VAT) and Slice Encoding for Metal Artifact Correction (SEMAC) techniques for the artifact reduction of patients during knee MRI with metal implants.
&#xD;

Materials and Methods: The MR images without any intervention of the knee from 20 patients with knee prostheses were used. The VAT and SEMAC metal artifact reduction techniques were applied to all the MR images. Volume and mass of the metal prosthesis were quantified using the MATLAB program and compared with the real measurements using nonparametric Wilcoxon tests in SPSS software. The qualitative analysis was performed by two blinded observers regarding the score of artifact size, distortions, image quality, and visualization of bone marrow and soft tissues adjacent to metal implants. In addition, Cohen&#x2019;s kappa values were used for inter-observer agreement.
&#xD;

Results: The average volume of the platinum based on the conventional, VAT, and SEMAC methods was estimated at 14.22 &#xB1; 0.43, 14.05 &#xB1; 0.4, and 13.3 &#xB1; 0.45 cm3, respectively. The statistical analysis showed no significant difference (P &gt; 0.05) between the mean value of the platinum volume for the SEMAC method and the real measurement (13.6 &#xB1; 0.33 cm3). Furthermore, regarding the conventional, VAT, and SEMAC sequences, the mean mass of the platinum was obtained at 305.02 &#xB1; 9.22, 301.37 &#xB1; 8.58, and 285.28 &#xB1; 9.65 g, respectively, with the P-Value of 0.005, 0.009, and 0.268, compared to the real measurements (286.81&#xB1;8.75 g). Notably, the blinded readers demonstrated that the SEMAC method was remarkably superior quality compared with VAT and conventional acquisitions (P-Value&lt; 0.05).
&#xD;

Conclusion: The knee prosthesis metal artifact was reduced using the VAT and SEMAC techniques, in a way that, the reduction was significant by the SEMAC method. In addition, concerning the qualitative observer analysis, the application of the SEMAC technique provides improved visualization of tissue structures adjacent to metal implants.</abstract>
    <web_url>https://fbt.tums.ac.ir/index.php/fbt/article/view/378</web_url>
    <pdf_url>https://fbt.tums.ac.ir/index.php/fbt/article/download/378/272</pdf_url>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Biomedical Technologies</JournalTitle>
      <Issn>2345-5837</Issn>
      <Volume>9</Volume>
      <Issue>4</Issue>
      <PubDate PubStatus="epublish">
        <Year>2022</Year>
        <Month>03</Month>
        <Day>05</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">The Evaluation of Contrast-to-Noise Ratio in CT Images Using Different Parameters of Gold Nanoparticles versus Omnipaque</title>
    <FirstPage>291</FirstPage>
    <LastPage>296</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Sara</FirstName>
        <LastName>Khademi</LastName>
        <affiliation locale="en_US">Mashhad University of Medical Sciences, Mashhad, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Hosein</FirstName>
        <LastName>Azimian</LastName>
        <affiliation locale="en_US">Mashhad University of Medical Sciences, Mashhad, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Hossein</FirstName>
        <LastName>Ghadiri</LastName>
        <affiliation locale="en_US">Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran, Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran, Preclinical Core Facility, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2021</Year>
        <Month>11</Month>
        <Day>08</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2021</Year>
        <Month>12</Month>
        <Day>12</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Purpose: Gold Nanoparticles (GNPs) with high density and an atomic number have lately been proposed as an alternative contrast agent for Computed Tomography (CT).
&#xD;

Materials and Methods: In the present study, the Contrast-to-Noise Ratio (CNR) of GNPs from various shapes, sizes, concentrations, and surface chemistry was compared with an iodine contrast agent using CT at different X-ray tube voltages and concentrations.
&#xD;

Results: Our findings showed that GNPs in various concentrations, shapes, sizes, and X-ray tube energies from 80 to 140 kVp revealed greater image CNR than iodinated contrast media (Omnipaque). Smaller spherical GNPs (13&#x202F;nm) had greater CNR than larger ones (60&#x202F;nm) and Gold Nanorods )GNRs( with a larger Aspect Ratio (AR) represented excellent effect on CNR. In addition, Polyethylene Glycol (PEG) covering on GNRs decreased CNR. We observed image CNR was increased using increasing in kVp and concentration.
&#xD;

Conclusion: Smaller spherical GNPs can be proposed as a potential candidate as a future of capillaroscopy system and ImageJ software with SIFT algorithm and Kalman filter, which can be used as an appropriate tool for determining the rate of nailfold blood flow velocity.</abstract>
    <web_url>https://fbt.tums.ac.ir/index.php/fbt/article/view/464</web_url>
    <pdf_url>https://fbt.tums.ac.ir/index.php/fbt/article/download/464/289</pdf_url>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Biomedical Technologies</JournalTitle>
      <Issn>2345-5837</Issn>
      <Volume>10</Volume>
      <Issue>1</Issue>
      <PubDate PubStatus="epublish">
        <Year>2022</Year>
        <Month>10</Month>
        <Day>01</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Emotion Recognition Using Continuous Wavelet Transform and Ensemble of Convolutional Neural Networks through Transfer Learning from Electroencephalogram Signal</title>
    <FirstPage>47</FirstPage>
    <LastPage>56</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Sara</FirstName>
        <LastName>Bagherzadeh</LastName>
        <affiliation locale="en_US">Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Keivan</FirstName>
        <LastName>Maghooli</LastName>
        <affiliation locale="en_US">Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Ahmad</FirstName>
        <LastName>Shalbaf</LastName>
        <affiliation locale="en_US">Department of Biomedical Engineering and Medical Physics, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Arash</FirstName>
        <LastName>Maghsoudi</LastName>
        <affiliation locale="en_US">Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2022</Year>
        <Month>01</Month>
        <Day>18</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2022</Year>
        <Month>04</Month>
        <Day>04</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Purpose: Emotions are integral brain states that can influence our behavior, decision-making, and functions. Electroencephalogram (EEG) is an appropriate modality for emotion recognition since it has high temporal resolution and is a noninvasive and cheap technique.
&#xD;

Materials and Methods:.A novel approach based on Ensemble pre-trained Convolutional Neural Networks (ECNNs) is proposed to recognize four emotional classes from EEG channels of individuals watching music video clips. First, scalograms are built from one-dimensional EEG signals by applying the Continuous Wavelet Transform (CWT) method. Then, these images are used to re-train five CNNs: AlexNet, VGG-19, Inception-v1, ResNet-18, and Inception-v3. Then, the majority voting method is applied to make the final decision about emotional classes. The 10-fold cross-validation method is used to evaluate the performance of the proposed method on EEG signals of 32 subjects from the DEAP database.
&#xD;

Results:.The experiments showed that applying the proposed ensemble approach in combinations of scalograms of frontal and parietal regions improved results. The best accuracy, sensitivity, precision, and F-score to recognize four emotional states achieved 96.90%&#xB1;0.52, 97.30&#xB1;0.55, 96.97&#xB1;0.62, and 96.74&#xB1;0.56, respectively.
&#xD;

Conclusion: So, the newly proposed model from EEG signals improves recognition of the four emotional states in the DEAP database.</abstract>
    <web_url>https://fbt.tums.ac.ir/index.php/fbt/article/view/453</web_url>
    <pdf_url>https://fbt.tums.ac.ir/index.php/fbt/article/download/453/277</pdf_url>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Biomedical Technologies</JournalTitle>
      <Issn>2345-5837</Issn>
      <Volume>10</Volume>
      <Issue>1</Issue>
      <PubDate PubStatus="epublish">
        <Year>2022</Year>
        <Month>06</Month>
        <Day>27</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Comparison of Average Absorbed Dose Distributions of Organs in SPECT-CT Imaging Using Monte Carlo Simulation</title>
    <FirstPage>57</FirstPage>
    <LastPage>65</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Shamim</FirstName>
        <LastName>Bagheri</LastName>
        <affiliation locale="en_US">Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modarres University, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Hossein</FirstName>
        <LastName>Rajabi</LastName>
        <affiliation locale="en_US">Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modarres University, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Ahmad</FirstName>
        <LastName>Bitarafan-Rajabi</LastName>
        <affiliation locale="en_US">Department of Medical Physics, Faculty of Medical Sciences, Iran Medical Sciences University, Tehran, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2021</Year>
        <Month>09</Month>
        <Day>18</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2022</Year>
        <Month>04</Month>
        <Day>21</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Purpose: The use of ionizing radiation in medical research, treatment, and diagnosis is inevitable and expanding day by day. Meanwhile, in two modes of Computed Tomography (CT) and Single Photon Emission Computed Tomography (SPECT) imaging, the dose received by the organs is featured with limitations and problems, which are often referred to as the CT Dose Index volume (CTDIvol.) and the Dose Length Product (DLP). This study aimed to estimate the average dose of organs and compare them in each of these two modalities.
&#xD;

Materials and Methods: Using the GATE code to simulate the SPECT-CT system and the ICRP voxelized phantom as the patient was investigated. The mean dose distribution in three groups of children, adults, and obese people with different body thicknesses was estimated. The dose received by each of the two systems was evaluated separately and results were discussed and analyzed comparatively.
&#xD;

Results: In the kidney, bladder, intestine, colon, liver, and gallbladder, the dose received in CT is at least 10% more than nuclear medicine. For example, the ratio of the dose received in CT to the dose received in nuclear medicine in the lung was about 1.08 and in the esophagus was about 1.24. Subsequently, the ratio increased to 0.25 in the bladder and 0.19 in the colon and intestine. Moreover, the major organs that received the maximum dose, result in CT at least 10% more than nuclear medicine.
&#xD;

Conclusion: The dose received in organs such as the esophagus, breast, and lung during CT imaging protocol and also maximum dose were at least ten percent more than nuclear medicine.</abstract>
    <web_url>https://fbt.tums.ac.ir/index.php/fbt/article/view/407</web_url>
    <pdf_url>https://fbt.tums.ac.ir/index.php/fbt/article/download/407/264</pdf_url>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Biomedical Technologies</JournalTitle>
      <Issn>2345-5837</Issn>
      <Volume>10</Volume>
      <Issue>1</Issue>
      <PubDate PubStatus="epublish">
        <Year>2022</Year>
        <Month>12</Month>
        <Day>28</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Mechanical performance separation of cardiac by nonlinear processing of Ultrasound B-mode images</title>
    <FirstPage>66</FirstPage>
    <LastPage>77</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Hamidreza</FirstName>
        <LastName>Fazilatnezhad</LastName>
        <affiliation locale="en_US">Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Parisa</FirstName>
        <LastName>Rangraz</LastName>
        <affiliation locale="en_US">Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Fereidon</FirstName>
        <LastName>Noshirvan Rahatabad</LastName>
        <affiliation locale="en_US">Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2021</Year>
        <Month>10</Month>
        <Day>06</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2022</Year>
        <Month>04</Month>
        <Day>30</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Accurate measurement of Left Ventricular Ejection Fraction (LVEF (is essential for the diagnosis and prediction of LV arrhythmias. This study aims to estimate LVEF using nonlinear and statistical processing in echocardiography images. The Cardiac Acquisition for Multi-Structure Ultrasound Segmentation (CAMUS) dataset is used to estimate LVEF. This dataset includes ultrasound images data from 60 patients in two different group (LVEF&gt;55%, LVEF&lt;45%). Region growing technique and Anatomical markers were used for segmentation of LV in images to measure area changes. LV area changes have been investigated using nonlinear and statistical analysis. In order to facilitate the process of estimating LVEF, feature extraction and an ANN has been used. The results show that: (1) LV area changes in LVEF&lt;45%, has a mean of (3.254) while LVEF&gt;55% has a lower mean of (3.071) but the mean of variance is (3.818) while for LVEF&lt;45% is (3.471) which can be concluded that the data scatter in LVEF&gt;55% was higher than the mean and indicates larger changes in the LV region. Estimated LVEF using nonlinear and statistical features is shows MSE of (5.15).</abstract>
    <web_url>https://fbt.tums.ac.ir/index.php/fbt/article/view/411</web_url>
    <pdf_url>https://fbt.tums.ac.ir/index.php/fbt/article/download/411/292</pdf_url>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Biomedical Technologies</JournalTitle>
      <Issn>2345-5837</Issn>
      <Volume>10</Volume>
      <Issue>1</Issue>
      <PubDate PubStatus="epublish">
        <Year>2022</Year>
        <Month>11</Month>
        <Day>23</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Quantitative Elemental Analysis Using Whole Spectral Information (with GA and MLR Methods) of Proton Induced Prompt Gamma-Rays Simulated Using Geant4 Toolkit</title>
    <FirstPage>78</FirstPage>
    <LastPage>87</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Fereshte</FirstName>
        <LastName>Saheli</LastName>
        <affiliation locale="en_US">Department of Energy Engineering, Sharif University of Technology, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Naser</FirstName>
        <LastName>Vosoughi</LastName>
        <affiliation locale="en_US">Department of Energy Engineering, Sharif University of Technology, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Zafar</FirstName>
        <LastName>Riazi</LastName>
        <affiliation locale="en_US">Physics and Accelerator Research School, Nuclear Science and Technology Research Institute, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Fatemeh S.</FirstName>
        <LastName>Rasouli</LastName>
        <affiliation locale="en_US">Department of Physics, K.N. Toosi University of Technology, Tehran, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Alireza</FirstName>
        <LastName>Jowkar</LastName>
        <affiliation locale="en_US">Physics and Accelerator Research School, Nuclear Science and Technology Research Institute, Tehran, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2022</Year>
        <Month>06</Month>
        <Day>27</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2022</Year>
        <Month>11</Month>
        <Day>09</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Purpose: Online determination of the elemental composition of tissues near the Bragg peak is a challenge in proton therapy related studies. In the present work, an analysis method based on the whole spectral information is presented for the quantitative determination of the elemental composition (weight %) of an irradiated target from its emitted Prompt Gamma (PG) spectrum.
&#xD;

Materials and Methods: To address this issue, four test phantoms with different weights (%) of 12C, 16O, 20Ca, and 14N elements were considered. The simulated PG spectra were recorded using 3 &#xD7; 3 inch NaI detectors. A library consisting of the spectra of single-element phantoms as well as the spectra of test-irradiated phantoms was produced for 30, 70, and 150 MeV incident protons using the Geant4 Monte Carlo toolkit. The elemental analysis was performed using the information of the whole spectrum by applying two methods, including the well-known Genetic Algorithm (GA) and Multiple Linear Regression (MLR).
&#xD;

Results: The results show that the proposed method estimates the oxygen concentration accurately. Furthermore, the estimated weights of other elements, with both methods, agree well with nominal values in each test phantom, for the considered energies.
&#xD;

Conclusion: The proposed quantitative elemental analysis of proton-bombarded phantoms using their induced PG spectrum is expected to be beneficial in treatment planning and treatment verification studies.</abstract>
    <web_url>https://fbt.tums.ac.ir/index.php/fbt/article/view/515</web_url>
    <pdf_url>https://fbt.tums.ac.ir/index.php/fbt/article/download/515/281</pdf_url>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Biomedical Technologies</JournalTitle>
      <Issn>2345-5837</Issn>
      <Volume>10</Volume>
      <Issue>1</Issue>
      <PubDate PubStatus="epublish">
        <Year>2022</Year>
        <Month>12</Month>
        <Day>03</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">A New Approach for Lie Detection Using Non-Linear and Dynamic Analysis of Video-Based Eye Movement</title>
    <FirstPage>88</FirstPage>
    <LastPage>95</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName>Mohamad Amin</FirstName>
        <LastName>Younessi Heravi</LastName>
        <affiliation locale="en_US">Department of Radiology and Medical Physics North Khorasan University of Medical Sciences, Bojnurd, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Morteza</FirstName>
        <LastName>Pishghadam</LastName>
        <affiliation locale="en_US">Department of Radiology and Medical Physics North Khorasan University of Medical Sciences, Bojnurd, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Emad</FirstName>
        <LastName>Khoshdel</LastName>
        <affiliation locale="en_US">Student Research Committee, Gonabad University of Medical Sciences, Gonabad, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Sajjad</FirstName>
        <LastName>Zibaei</LastName>
        <affiliation locale="en_US">Student Research Committee, North Khorasan University of Medical Sciences, Bojnurd, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2022</Year>
        <Month>06</Month>
        <Day>11</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2022</Year>
        <Month>09</Month>
        <Day>14</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Purpose: This study aimed to evaluate a lie-detection system by non-linear analysis of video-based eye movement.
&#xD;

Materials and Methods: The physiological signals, as well as video-based eye movement in horizontal and vertical channels, were recorded based on a Control Question Test (CQT). The dynamics of eye movement signals were then analyzed by Recurrence Quantification Analysis (RQA). Statistical analysis was performed by ANOVA and Linear Discriminate Analysis (LDA).
&#xD;

Results: In this study, 40 subjects participated. The statistical analysis results of vertical eye movement indicated that ENT measures increased significantly for relevant questions in comparison to other questions. Moreover, a significant increase was observed in all RQA parameters except Lmax and DET for horizontal eye movement. The results of LDA using psychophysiology features. The accuracy percentage of 78.4% and 81.86% were obtained for lie detection using physiological signals and optimal RQA parameters of video-based eye movements, respectively.
&#xD;

Conclusion: The accuracy of lie detection by significant RQA parameters was more than the accuracy of physiological signals. So, the results of this study illustrate that the dynamic technique is well suited to analyze eye movement signals under stress and it could be recommended as a useful method in lie detection.</abstract>
    <web_url>https://fbt.tums.ac.ir/index.php/fbt/article/view/505</web_url>
    <pdf_url>https://fbt.tums.ac.ir/index.php/fbt/article/download/505/282</pdf_url>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Biomedical Technologies</JournalTitle>
      <Issn>2345-5837</Issn>
      <Volume>10</Volume>
      <Issue>1</Issue>
      <PubDate PubStatus="epublish">
        <Year>2022</Year>
        <Month>08</Month>
        <Day>27</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Comparison of Hematological Parameters between Diagnostic Radiation Workers and Non-Radiation Workers</title>
    <FirstPage>96</FirstPage>
    <LastPage>101</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Mohammad</FirstName>
        <LastName>Keshtkar</LastName>
        <affiliation locale="en_US">Department of Medical Physics and Radiology, Faculty of Medicine, Gonabad University of Medical Sciences, Gonabad, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Nastaran</FirstName>
        <LastName>Khaghani</LastName>
        <affiliation locale="en_US">Student of General Medicine, Faculty of Medicine, Gonabad University of Medical Sciences, Gonabad, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Maliheh</FirstName>
        <LastName>Ziaee</LastName>
        <affiliation locale="en_US">Department of Community Medicine, School of Medicine, Social Determinants of Health Research Center, Gonabad University of Medical Sciences, Gonabad, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>Sajad</FirstName>
        <LastName>Pandesh</LastName>
        <affiliation locale="en_US">Department of Radiology Technology, School of Allied Medicine, Birjand University of Medical Sciences, Birjand, Iran</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2022</Year>
        <Month>03</Month>
        <Day>08</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2022</Year>
        <Month>06</Month>
        <Day>14</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Purpose: Radiation workers are exposed to chronic effects due to long-term exposure to low levels of ionizing radiation. One of the biological indicators to evaluate these chronic radiation effects is the study of the hematopoietic system. The purpose of this study is to compare the changes in blood parameters of radiology staff and staff of other wards of the hospital.
&#xD;

Materials and Methods: In this study, 47 radiology staff working in the radiology department of the hospital as the study group and 98 personnel in other departments as the control group were included. Demographic data including age, gender, and work experience were obtained. Hematological parameters were extracted from the complete blood count tests of participants.
&#xD;

Results: The results of this study showed that the MCH and MCHC parameters significantly decreased in the male study group, whereas no significant differences were observed in the blood parameters of the female study group in comparison to those of the control group. There was a significant positive correlation between the parameters of Hemoglobin and age. There was a significant negative correlation between work experience and white blood cells, while there was a significant positive correlation between work experience and Hemoglobin.
&#xD;

Conclusion: Correlation between collective absorbed dose and changes in blood parameters is suggested for future studies. Based on the results of this study and other studies, it can be concluded that long-term exposure to low levels of radiation may change blood parameters. Therefore, regular and periodic complete blood count tests along with absorbed dose monitoring of radiation workers are recommended.</abstract>
    <web_url>https://fbt.tums.ac.ir/index.php/fbt/article/view/471</web_url>
    <pdf_url>https://fbt.tums.ac.ir/index.php/fbt/article/download/471/276</pdf_url>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>Frontiers in Biomedical Technologies</JournalTitle>
      <Issn>2345-5837</Issn>
      <Volume>10</Volume>
      <Issue>1</Issue>
      <PubDate PubStatus="epublish">
        <Year>2022</Year>
        <Month>12</Month>
        <Day>12</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Critical Organ Dose Estimation from Tc-99m-MIBI in Nuclear Medicine Cardiology Based on Distribution Data in Rats</title>
    <FirstPage>102</FirstPage>
    <LastPage>108</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Gholamreza</FirstName>
        <LastName>Fallahmohammadi</LastName>
        <affiliation locale="en_US">Department of Radiology, Faculty of Allied Medicine, Mazandaran University of Medical Sciences, Sari, Iran</affiliation>
      </Author>
      <Author>
        <FirstName>A